Aerovent Fans: Florida Wildfires Fan” Demand for New Water Production Facilities

January 14th, 2011

Florida Wildfires “Fan” Demand for New Water Production Facilities
Aerovent Chosen by Jacksonville Electric Authority & CH2M Hill For Emergency Water Plant Construction Projects

Voluntary water rationing is almost a way of life in Florida. During hot summer months, watering lawns and washing cars are restricted to minimize peak demands on municipal water plants.

Over the past decade, drought conditions have spawned many large forest fires, making water rationing mandatory. At one point several years ago, almost every county in Florida was on fire and thousands of residents were evacuated from their homes. These devastating wildfires magnified the need for newer and larger water production facilities.

The gases and chemicals present in water and wastewater treatment facilities cause corrosion, equipment failures, plant shutdowns, and increased maintenance and operation costs. In some applications, these corrosive gases and chemicals cause odor complaints, unsafe working conditions, and can even be explosive. Chlorine, methane and hydrogen sulfide are lethal gases typical to these industrial facilities. The air handling systems and equipment used in these installations must be designed for each specific application. Standard commercial grade HVAC equipment is not suitable for these types of corrosive environments.

Aerovent equipment has been the basis of design for the City of Jacksonville’s water and wastewater treatment facilities for over ten years. Each fan is custom built to a set of specifications designed for a specific application. For instance, Aerovent’s fiberglass axial “TF” fans are used for forced draft aeration and dilution ventilation for Jacksonville’s ground water reservoirs. A two-million gallon reservoir has six Aerovent 43" TF fans exhausting a total of 120,000 CFM. The TF fans are sized to exhaust one air change per minute, based on the average high and low water levels inside the tanks. Fresh air is drawn through the screened aerators and overflow vents. The large volumes of fresh air mix with the aeration process to dilute and substantially reduce overall levels of corrosive gases. The fans are staggered to distribute the air and eliminate condensation and corrosion on the interior tank surfaces.

The photograph above shows two reservoirs at the Ridenour Regional Water Treatment Plant with twelve Aerovent 43" TF fans. The Brierwood Water Treatment Plant currently under construction has five reservoirs utilizing twenty Aerovent 43" TF fans. Other completed projects include the Mayo Clinic WTP (6 fans), the Community Hall WTP (6 fans), and the Julington Creek WTP (6 fans).

These municipal water production facilities are required to pass a variety of tests and inspections prior to receiving an operating permit. Insects carry disease and are considered a health hazard. The tank vent fans are inspected by the Department of Health for “insect-proof” construction. Fan curb bases and exhaust dampers are specified with “continuous, insect-proof neoprene gaskets mechanically fastened with 316 stainless steel hardware.” Adhesives are not acceptable because the gaskets of some manufacturers have come off and fallen into the tanks. Improper gaskets will delay the plant operating permit until approved by the Department of Health and accepted by the owner. Aerovent has designed and furnished a special gasket arrangement to meet these requirements. (See Figure 1 and photo at right.)

Rust is also a health hazard on a water production facility. The specifications call for all-fiberglass construction with type 316 stainless steel shaft, motor pedestal, motor slide base, lube lines and hardware, inside and out. Coated or encapsulated steel is not acceptable.

Aerovent’s fiberglass fans are molded, and the structural integrity is achieved through extra thickness. (See photo above, at left.) The one-piece, solid FRP propeller is straight bored and keyed to a stepped 316 stainless steel shaft. (See photo, at right.) Figure 2 shows two Type 316 stainless steel collar washers (A) and a 316 stainless steel bolt threaded into the end of the shaft to secure the propeller (B). This construction facilitates easy propeller removal for access to shaft seals and fan bearings. The shaft seals shown in Figure 3 isolate the bearings from the corrosive exhaust air and maintain “insectproof” construction.

Commercial grade products coat carbon steel with fiberglass to build strength and lower manufacturing costs. Propellers typically have carbon steel hubs coated with fiberglass and are secured to carbon steel fan shafts with taper-lock carbon steel bushings. The top of the bushing is resin and gel coated prior to shipment. To access the shaft seal and bearings, the resin coating must be cut off. Many times a wheel puller is required to pull the hub away from the shaft. The fiberglass becomes cracked, the fan balance is affected, and the corrosion resistant integrity is lost.

Aerovent’s 316 stainless steel motor bases are bolted between the two integral FRP fan flanges to form a rigid structure. The fan motors are positioned and mounted for alignment of sheaves and belts. Belts are tensioned by loosening four bolts in the slotted stainless steel bases. On larger horsepower motors (or where specified by the owner) 316 stainless steel NEMA motor slide bases are furnished to facilitate easy belt tensioning and replacement. FRP weather enclosures are furnished to cover the motors. (See photo at right.)

Commercial manufacturers encapsulate a carbon steel plate and cantilever a painted carbon steel motor base on four jack bolts. Belt tensioning and alignment problems occur frequently with this arrangement. Over a period of time, the weight of the motor, the lever-type force applied from tensioning the belts, and the vibration from the rotating motor and propeller cause the fiberglass and steel plate to separate. The painted steel motor bases and standard painted steel motor covers rust quickly. The rust streaks the tanks and can be seen easily from a distance.

Bearing lubrication lines and grease fittings typically furnished in copper, brass or bronze are attacked by chlorine. Lube lines and fittings furnished on Aerovent’s fans are all 316 stainless steel.

The color of the fans is matched to the building color. This is done by pigmenting the fiberglass resin and has an advantage over a painted surface: the coloration cannot chip or loosen from the surface, discoloring the fan.

FRP curb bases must be anchored to poured-in-place concrete curbs through the side to eliminate leaking. A minimum 4" overlap is specified to keep anchors from cracking the edges of the concrete surfaces. Fan bases are curved to reduce pressure losses and corrosion due to fan inlet velocities. Flanges are turned out so that bolted fan connections are weatherproof and out of the airstream. (See photo at right.)

These fans run 24 hours per day, 365 days per year. One 20,000 CFM fan handles 1080 tons of corrosive air each day. Fan shafts are 316 stainless steel, and bearings are oversized to provide extended operating life. The large 34° pitched, seven-bladed FRP propellers provide quiet and stable performance as water levels change and inlet screens become dirty. The vertical upblast design discharges exhaust air at high velocities into the wind to become further diluted.

Aerovent’s engineering and manufacturing capabilities and industrial quality products have made them the best solution in solving the most difficult and demanding ventilation problems presented by water and wastewater treatment facilities.

Contact Fluid Engineering at 1-800-841-9944 for help with your fan application!

Smoot Dense Phase Pneumatic Conveying

January 7th, 2011

CONCEPT In dry materials handling, the product being conveyed and the application are used to determine the best type of conveying system. Highly abrasive products and those subject to degradation move best through a high-pressure, low-velocity conveying system. On long distance, high-rate applications, a high-pressure, low-velocity system can offer energy savings. Smoot Dense Phase Pneumatic […]

Seepex: Traffic Safety Despite Ice and Snow

December 31st, 2010

Traffic safety despite ice and snow. Ice on the wings or the tail of an airplane changes the airflow and causes an undesired increase in weight. Ice and snow particles can break off and damage the engines or the tail unit. For the prevention of these risks airplanes are treated with environment-friendly de-icing agents before […]

Tuthill Global Gear Process Pumps

December 24th, 2010

Tuthill Global Gear Pumps Tough Pumps with Field Proven Reliability Fluid Engineering is pleased to represent Tuthill and its Global Gear line of internal gear process pumps.  GlobalGear® builds on a time-tested design and more than 80 years of gear pump engineering experience. Capable of tackling the toughest highviscosity applications, the GlobalGear® Process Pump handles everything from bulk transfer, chocolate […]

Fluid Engineering presents Sulzer’s AHLSTAR UP

December 17th, 2010

AHSTARUP – A Modern Range of Stock and Process Pumps for Constant Energy Consumption Savings and Enhanced Operational Reliability without Sealing Water AHLSTARUP further development of the reliable AHLSTARTM stock and process pumps, also known as APT pumps, used in the pulp and paper industry all over the world. The continuous improvement of processes in […]

Warren Rupp and Fluid Engineering Provide Rugged Mining Duty AOD Pumps for Above and Below Ground Se

December 10th, 2010

Warren Rupp and Fluid Engineering Provide Rugged Mining Duty AOD Pumps for Above and Below Ground Service Fluid Engineering is proud to represent Warren Rupp and its full line of mine duty pumps for both above and below ground applications. Warren Rupp Standard Duty Metallic Pumps are ideal for mine duty applications. They are well-suited […]

Taylor Products: IBC 2000 Bulk Bag Unloader

December 6th, 2010

Taylor Products: IBC 2000 Bulk Bag Unloader Taylor’s IBC 2000 is adaptable to nearly any discharge or deweigh application. It is constructed of heavy duty tubular steel with a compact footprint of 60 in by 60 in. The IBC 2000 can be easily modified with any of its multiple options in order to handle your […]

On-Site Test Blows Away Skepticism of Torit PowerCore® Cleanability

December 3rd, 2010

"But will it pulse clean?" was the facility manager's first question when he was introduced to a PowerCore® filter pack from Donaldson® Torit®. "The theory behind PowerCore is technically valid but the media looks strange compared to a baghouse filter," he commented. "I doubted the narrow channels of the media pack could be pulsed cleaned." […]

Fluid Engineering and ProMinent Supply Cooling Tower Chemical Feed Skids for Water Treatment

November 26th, 2010

Fluid Engineering and ProMinent Supply Cooling Tower Chemical Feed Skids for Water Treatment Fluid Engineering received an inquiry from a local utility with a need for pumps to feed chemicals for cooling tower water treatment. It requested seven (7) Cooling Tower Chemical Feed Skids. Each skid was too include primary and backup pumps with capability […]

Fluid Engineering is proud to represent the Fybroc Advantage!

November 19th, 2010

Fluid Engineering is proud to represent Fybroc's line of fiberglass reinforced pumps and the FYBROC ADVANTAGE!  Experience – Fiberglass Reinforced Pumps are Our Only Business! As the first company to develop a fiberglass reinforced pump in 1966, Fybroc has continued to focus on non-metallic pumps for the past 30 years. Design – Advanced Composite Pump Designs! […]